How to Test a Hot Tub Heater Element
Quick answer
With the power off at the breaker, disconnect the heater element terminals and measure resistance across them with a multimeter. A working 240-volt element of around 4 to 5.5 kW typically reads roughly 10 to 15 ohms; an open circuit (OL) means it's burned out. Also check from each terminal to the heater's metal housing: any reading other than open means a short to ground, which trips the GFCI.
How to test it
- Turn off power at the breaker and GFCI disconnect, and confirm with a tester.
- Open the control box and find the heater terminals.
- Photograph the connections, then disconnect them.
- Set the multimeter to ohms. Measure across the two element terminals.
- Compare with the expected value for your element's wattage and voltage. Roughly: resistance = volts squared divided by watts.
- Measure from each terminal to the heater tube or ground lug. It should read open circuit.
- Reconnect everything exactly as it was.
| Element | Approximate resistance |
|---|---|
| 5.5 kW at 240V | About 10.5 ohms |
| 4 kW at 240V | About 14.4 ohms |
| 1 kW at 120V | About 14.4 ohms |
Parts for this repair
Always match the model and part number on your appliance's data plate or the old part before ordering.
- Digital multimeter
- Hot tub heater element
- Hot tub heater assemblyMatch your control system.
Links go to eBay search results. We may earn a commission.
When to call a technician
If you're not confident working inside the control box, a technician can test the heater in minutes.